Test 1

The first test was performed with a normal AC Motor

 

Fig.1:Experimental current spectra of normal motor at 30 Hz supply freq. and 0.0089 slip.


 

 

Fig.2:Experimental current spectra of normal motor at 38 Hz supply freq. and 0.0070 slip.

 

 

 

Fig.3: Experimental current spectra of normal motor at 47 Hz supply freq. and 0.0067 slip.

 

 

Attachment: Data of normal AC motor at 30 Hz supply
Attachment: Data of normal AC motor at 38 Hz supply
Attachment: Data of normal AC motor at 47 Hz supply